A drain position is only useful if you know what it was measured from. Buyers have received pans listed with an 18-inch drain position that measured 17 inches on the actual unit — a one-inch miss that only shows up after the trap is roughed in and the pan will not sit on it. The fix is not a better catalogue; it is a better habit: measure and specify every drain position from the face of the stud, confirm it on the signed model drawing for the exact model you ordered, and never rough in plumbing from a headline dimension on a listing page. For US-format SMC pans, the range covered on this site runs 36–60 inches by 30–48 inches with a 4-inch profile and a 2-inch drain connection — but within that range, drain position is a per-model fact, not a range fact.
By the SMC Shower Engineering Team · Last updated: November 2026
Why do published drain dimensions turn out wrong?
Four causes account for nearly every mismatch buyers report. First, different reference points: one seller measures from the outside edge of the pan, another from the finished wall, another from the stud face — the same physical drain produces three different numbers. Second, rounded conversions: a dimension originally specified in millimetres gets rounded to the nearest inch for a US listing, and a rounding that is harmless for length is a failure for a drain centre. Third, one listing covering several models: end-drain, centre-drain and offset variants of the same pan size share a product page, and the dimension shown belongs to only one of them. Fourth, stale drawings: a mould revision moves the drain, the listing is never updated, and the warehouse ships the current mould against the old number. None of these is detectable from the listing itself, which is why the verification steps below exist.
How do you measure drain position from the stud?
- Work from the framing, not the finished wall. Before board and tile, your fixed reference is the face of the studs. Measure from the stud face on the drain wall to the centre of the drain hole in the subfloor. Tile and board thicknesses are added later and vary by build-up, so a dimension taken from a finished surface cannot be reproduced at rough-in stage.
- Measure both axes. Record the distance from the back-wall stud face to the drain centre, and from the side-wall stud face to the drain centre. A single dimension only locates the drain on one axis; installers have roughed in a perfectly measured drain on the wrong line because the second axis was assumed to be centred.
- Measure to the centre, not the edge. Hook the tape on the stud face and read to the middle of the drain opening or the waste fitting centreline. Edge readings shift with fitting size.
- Write it down in inches and fractions, exactly as read — for example 17 1/2 in from the back stud, 16 in from the side stud — and photograph the tape in place. A photo of a tape measure against framing settles arguments that memory loses.
- Compare against the model drawing, not the listing. The drawing for the model you ordered should state drain position from the pan edges; convert your stud-face measurement by adding the pan’s setback from the framing (the pan edge sits against the studs, so drawing edge = stud face line in most alcove installs — confirm this on the drawing rather than assuming it).
What should I verify before I rough in? Use this worksheet
Fill in one row per model before the plumber sets a single pipe. Any cell you cannot fill in from the model drawing is a question to the supplier — asked before the order ships, not after the pan lands.
| Field to verify on the model drawing | Why it matters | Your confirmed value |
|---|---|---|
| Exact model code and drain variant (centre / end / offset) | Variants of one pan size have different drain positions; the listing dimension may belong to another variant | To be completed per model |
| Drain centre from back edge of pan (inches) | Sets the trap position from the back-wall stud face | To be completed per model |
| Drain centre from side edge of pan (inches) | Confirms whether the drain is truly centred on the short axis | To be completed per model |
| Drain connection size | US-format pans on this site use a 2-inch drain connection — confirm the waste kit matches; check local code | To be completed per model |
| Pan overall length × width and profile height | US-format range: 36–60 in × 30–48 in, 4-inch profile — confirm your model’s exact size, not the range | To be completed per model |
| Tiling flange / threshold edges present on which sides | Decides alcove vs corner fit and where the pan edge meets the studs | To be completed per model |
| Drawing revision date | Guards against the stale-drawing problem: the drawing must match the current mould | To be completed per model |
What does a confirmed drain position actually look like? The L-12080 drawing
One fully dimensioned example is worth more than a page of ranges. The factory technical drawing for the Serie L model L-12080 (1200 × 800 × 26 mm) states: a 126 mm square drain cover on top, a 90 mm waste outlet underneath, and the centre of the waste outlet 200 mm from the short edge of the pan. That single line is what you rough in against — measured from the pan edge, to the centre of the outlet, in writing, on the drawing for the exact model.
| Item (model L-12080) | Drawing value |
|---|---|
| Pan size (L × W × H) | 1200 × 800 × 26 mm |
| Drain cover (top) | 126 mm square |
| Waste outlet (underside) | 90 mm |
| Waste outlet centre from short edge | 200 mm |

The same size guide lists all 30 Serie L models at a 26 mm height, in 700, 800 and 900 mm widths and 800–1800 mm lengths. Drain positions for the other models follow the same drawing-per-model rule: the value above belongs to the L-12080 only, and every other model is confirmed on its own current drawing before rough-in — which is exactly what the worksheet above is for.
What is the pre-order verification checklist?
- Ask for the model drawing (PDF) for the exact model code and drain variant — not the series brochure.
- Check the drawing’s revision date and ask whether the drain position has changed since the previous revision.
- Convert every drain dimension to inches and fractions yourself; do not rely on a converted listing value.
- Confirm the drain connection size and which waste kit the supplier ships with the pan.
- On a multi-unit order, agree that production follows the confirmed drawing, and keep the confirmed copy with the order paperwork.
- On delivery of the first unit, measure the actual pan against the drawing before releasing the rest of the installation schedule — a two-minute tape check on unit one protects every unit after it.
- Plan the installation sequence around the confirmed position using our SMC pan installation guide, which covers bedding, support and the drain connection in order.
The drain is off by an inch. What are my options?
If the pan is right and the rough-in is wrong, moving the trap is usually the cheaper correction: an inch of offset at rough-in stage is a fitting change, while forcing the pan to fit means offsetting the waste connection under load, which stresses the drain boss and voids the point of a moulded pan. If the pan itself does not match its confirmed drawing, stop, photograph the tape against the pan, and raise it with the supplier with the drawing attached — that is a documentation conversation, and the side with the dated drawing and the dated photo wins it. What you should not do is enlarge the drain hole in the pan or shim the pan sideways to meet the pipe: both convert a measurement problem into a structural one.
Frequently asked questions
Should I measure drain position from the finished wall or the stud?
From the stud face. Rough-in happens before wall finishes exist, and finish thickness varies with board and tile choices. A stud-face dimension can be reproduced on any job; a finished-wall dimension cannot.
Why was my pan’s drain an inch off from the listing?
The most common causes are a dimension measured from a different reference point, a millimetre value rounded to the nearest inch during listing conversion, or a listing that covers several drain variants with one number. This is a known buyer complaint — pans listed at 18 inches that measure 17 inches — and it is exactly why we tell buyers to verify against the model drawing.
What drain size do US-format SMC pans use?
The US-format pans covered on this site use a 2-inch drain connection. Confirm the waste kit supplied with your model matches, and check local code for the trap and venting requirements in your jurisdiction.
Can I get the drain position for a specific model before ordering?
Yes — ask for the model drawing for the exact model code and variant, and verify the two axis dimensions on it before you commit. If a supplier cannot produce a drawing, treat that as information about the supplier, not just about the pan.
Need a model drawing checked against your rough-in plan? Request a quote and include the model codes you are considering.